Evaluation of the Influence of Ambient Temperature on the Performance of the Trans-Amadi Gas Turbine Plant
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Journal of Power and Energy Engineering
Abstract
This paper examines the effects of ambient temperature on the Trans-Amadi gas
turbine power station Phase II. The investigation took thirteen (13) months (January
2012 to January 2013) during which plant data were monitored and operational
Logsheets like turbine logsheets, plant—auxiliaries’ logsheets and generator logsheets
were studied. The gas turbine (GT) that was under investigation was GT-2: MS5001
Nuovopignone with designed installed capacity of 25.0 Megawatts (MW). The result
of the study shows that a 1˚C rise of the ambient temperature is responsible for the
following: 0% - 0.12% decrease in the power output, 0% - 0.12% increase in the pow
er differential, 0% - 1.17% decrease in the thermal efficiency, 0% - 27.18% increase in
the heat rate and 0% - 3.57% increase in the specific fuel consumption. An ambient
temperature of 30˚C is found to yield minimal fuel consumption.
Description
Citation
Igoma et al., 2016