Performance Appraisal of The Trans - Amadi Gas Turbine Power Station
Loading...
Date
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
IRE JOURNALS
Abstract
The performance appraisal of the Trans -
Amadi Gas Turbine Power Station has been done.
The studied which encompasses collection of data
from actual plant operational logsheets: turbine log
sheets, plant/Auxiliaries logsheets and generator
logsheets for the months of February, 2011 to
November 2011. Parameters which could not be
directly measured or determined were derived
utilizing appropriate thermodynamic equations and
principles. The work also reveal that an increment of
ambient temperature from 250C to 340C , the power
output decreases by 0.08MW, the thermal efficiency
decreases by 3.77%, the heat supplied decreases by
421KW, the air fuel ratio increases by 5.22, the
specific fuel consumption increases by 0.102Kg/KWh
and the heat rate increases by 0.23KCal/Wh
respectively. The performance of the gas turbine
plant revealed that the plant will consume much fuel
for small amount of workdone: that is, there is
tendency for poor power supply. It is recommended
that routine maintenance should be carried out
periodically and if the symptoms persist, intercoolers
should be introduced in order to control the ambient
temperature which is the cause.
Description
Citation
Igoma & Tonlagha, 2021